IBM 53959KX 81Y2321 11kVa 11000VA 10KW Rack Mount 5U 230V 1Ph Battery Back UPS
IBM 53959KX 81Y2321 11kVa 11000VA 10KW Rack Mount 5U 230V 1Ph Battery Back UPS
IBM 53959KX 81Y2321 11kVa 11000VA 10KW Rack Mount 5U 230V 1Ph Battery Back UPS
IBM 53959KX 81Y2321 11kVa 11000VA 10KW Rack Mount 5U 230V 1Ph Battery Back UPS
IBM 53959KX 81Y2321 11kVa 11000VA 10KW Rack Mount 5U 230V 1Ph Battery Back UPS

IBM 53959KX 81Y2321 11kVa 11000VA 10KW Rack Mount 5U 230V 1Ph Battery Back UPS

Product Brand: IBM
Product Condition: Used
Excluding VAT: £2,137.50
Including VAT: £2,565.00
Information
IBM 53959KX 81Y2321 11000VA 10KW Rack Mount 5U 230V 1Ph UPS
In Good Condition And Full Working Order
Batteries Installed
Full Load 5min & Half Load 14min Runtime
Included:-
1 x IBM 5395-9KX 11000VA 10000w LCD 5U Rack UPS (208V/230V)
1 x Eaton Lenovo IBM UPS Network Management Card 00W0C523 710-U0086-04P
1 x Set Rack Mount Rails
Specification
IBM 11000VA LCD 5U Rack UPS (208V/230V)
IBM part number 5395-9KX
VA/Watts rating 11000 VA/10000 W
Nominal output voltage (Vac) 208 V/230 V auto sensing at first powerup, userconfigurable
Rated power output 11000 VA (normal and high efficiency modes)5500 VA (double conversion mode)
Output power capacity in watts 10000 W (normal and high efficiency modes)5000 W (double conversion mode)
Load segments Two
Output connections Eight IEC 320 C19
Circuit breakers Four two-pole output breakers rated at 20 A (two breakersfor each load segment)
Efficiency Normal mode: 93%High efficiency mode: 96%Battery mode: 90%
Input
Nominal input voltage 208 V/230 V (auto sensing at first powerup)
Maximum input current 69.96 A (line mode)58.33 A (battery mode)
Input frequency (auto sensing) 50/60 Hz +/- 3 Hz
Input connection type Hardwired to terminal block
Included line (input) cords None
Input voltage range, mains operations 155-255 V for 208 V
Batteries
Battery type Valve Regulated Lead Acid (VRLA): maintenance-free,sealed, leak-proof
Typical recharge time 3 hours to 90% charge from a UPS/battery discharge of50% rated load
Communications and management
USB port Yes
RS-232 serial port Yes
Ethernet port Optional using Network Management Card, 46M4110Environmental Monitoring Probe Optional
Environmental Monitoring Probe, 46M4113
Surge protection and filtering
Surge energy rating 1300 Joules
Filtering ANSI/IEEE C62.41; 1991 CATEGORYB3 (SURGE)
Physical specifications and operating environment
The physical specifications of the 5U uninterruptible power supply are as follows:
Height: 212 mm (8.3 in.)
Width: 483 mm (19 in.)
Depth: 740 mm (29.1 in.)
Weight: 99 kg (218 lb)
The IBM 11000VA LCD 5U Rack UPS is supported in the following operating environment:
Temperature: 0 - 40.0° C (32 - 104° F) at 0 - 2,000 m (0 - 6,600 ft)
Relative humidity: 5 - 95%
Maximum altitude: 3,048 m (10,000 ft)

VAT IS NOT PAYABLE BY PURCHASERS OUTSIDE OF THE UK

SL

To request a price please fill out the form below...


Close